CVE-2025-62172

  • Published: 2025-10-14T16:15:41.513

Home Assistant is open source home automation software that puts local control and privacy first. In versions 2025.1.0 through 2025.10.1, the energy dashboard is vulnerable to stored cross-site scripting. An authenticated user can inject malicious JavaScript code into an energy entity’s name field, which is then executed when any user hovers over data points in the energy dashboard graph tooltips. The vulnerability exists because entity names containing HTML are not properly sanitized before being rendered in graph tooltips. This could allow an attacker with authentication to execute arbitrary JavaScript in the context of other users’ sessions. Additionally, if an energy provider (such as Tibber) supplies a malicious default name for an entity, the vulnerability can be exploited without direct user action when the default name is used. This issue has been patched in version 2025.10.2. No known workarounds exist.

Related CVE by CWE

No related CWE found.

Top CVE for Vendor

No vendor taxonomy on this entry.

Recently Exploited Similar Vulnerabilities

No recent KEV-listed items for this vendor/product.

How to fix CVE-2025-62172

CVE-2025-62172 is a unknown severity vulnerability affecting the affected product.

Description: Home Assistant is open source home automation software that puts local control and privacy first. In versions 2025.1.0 through 2025.10.1, the energy dashboard is vulnerable to stored cross-site scripting. An authenticated user can inject malicious JavaScript code into an energy entity’s name field, which is then executed when any user hovers over data points in […]

Affected Versions:
Vulnerable: 2025.1.0 - 2025.10.1
Safe: ≥ 2025.10.2

Exploit Difficulty: HARD
⏱️ Time to exploit: > 4 hours
🛠️ Required skills: Advanced security expertise
💰 Public exploits: Rare or not public

How to Fix:

1 Identify affected systems

- Check if you're running the affected product
- Verify version (vulnerable: 2025.1.0 - 2025.10.1)

2 Immediate actions

- Update to ≥ 2025.10.2 or later
- If patching is not immediately possible: restrict network exposure, apply least-privilege access

3 Verification

- Test the fix in a staging environment first
- Review logs for signs of exploitation
- Monitor for IOCs (Indicators of Compromise)

4 Long-term prevention

- Enable automatic security updates
- Set up vulnerability monitoring
- Review and harden security configurations

Exploit Difficulty Assessment

HARD
⏱️ Time to Exploit: > 4 hours
🛠️ Skills Required: Advanced security expertise
💰 Public Exploits: Rare or not public

Affected Versions

Vulnerable: 2025.1.0 - 2025.10.1
Safe: ≥ 2025.10.2

Vulnerability Timeline

Oct 14, 2025
Vulnerability Published

CVE details first published to NVD database

Nov 12, 2025
Imported to Database

Added to this CVE tracking system

Detection Rules & IOCs

No specific detection rules generated for this vulnerability type.

No vendor/product data available.