CVE-2025-14095
- CVSS Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Published: 2025-12-17T12:15:45.570
A “Privilege boundary violation” vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.
Other related CVE’s are CVE-2025-14096 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required configuration for Exposure:
Physical access to the analyzer is needed.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication. Note:
CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems.
Related CVE by CWE
No related CWE found.
Top CVE for Vendor
No vendor taxonomy on this entry.
Recently Exploited Similar Vulnerabilities
No recent KEV-listed items for this vendor/product.
How to fix CVE-2025-14095
Description: A “Privilege boundary violation” vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software. Other related CVE’s […]
Exploit Difficulty: MEDIUM
⏱️ Time to exploit: 1-4 hours
🛠️ Required skills: Intermediate security knowledge
💰 Public exploits: May be available
How to Fix:
- Check if you're running the affected product
- Update to the latest patched version
- If patching is not immediately possible: restrict network exposure, apply least-privilege access
- Test the fix in a staging environment first
- Review logs for signs of exploitation
- Monitor for IOCs (Indicators of Compromise)
- Enable automatic security updates
- Set up vulnerability monitoring
- Review and harden security configurations
Exploit Difficulty Assessment
Vulnerability Timeline
CVE details first published to NVD database
Added to this CVE tracking system
Detection Rules & IOCs
No specific detection rules generated for this vulnerability type.
No vendor/product data available.