CVE-2025-14038
- CVSS Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H
- Published: 2025-12-15T18:15:47.100
EDB Hybrid Manager contains a flaw that allows an unauthenticated attacker to directly access certain gRPC endpoints. This could allow an attacker to read potentially sensitive data or possibly cause a denial-of-service by writing malformed data to certain gRPC endpoints. This flaw has been remediated in EDB Hybrid Manager 1.3.3, and customers should consider upgrading to 1.3.3 as soon as possible.
The flaw is due to a misconfiguration in the Istio Gateway, which manages authentication and authorization for the affected endpoints. The security policy relies on an explicit definition of required permissions in the Istio Gateway configuration, and the affected endpoints were not defined in the configuration. This allowed requests to bypass both authentication and authorization within a Hybrid Manager service.
All versions of Hybrid Manager – LTS should be upgraded to 1.3.3, and all versions of Hybrid Manager – Innovation should be upgraded to 2025.12.
Related CVE by CWE
No related CWE found.
Top CVE for Vendor
No vendor taxonomy on this entry.
Recently Exploited Similar Vulnerabilities
No recent KEV-listed items for this vendor/product.
How to fix CVE-2025-14038
Description: EDB Hybrid Manager contains a flaw that allows an unauthenticated attacker to directly access certain gRPC endpoints. This could allow an attacker to read potentially sensitive data or possibly cause a denial-of-service by writing malformed data to certain gRPC endpoints. This flaw has been remediated in EDB Hybrid Manager 1.3.3, and customers should consider upgrading […]
Exploit Difficulty: MEDIUM
⏱️ Time to exploit: 1-4 hours
🛠️ Required skills: Intermediate security knowledge
💰 Public exploits: May be available
How to Fix:
- Check if you're running the affected product
- Update to the latest patched version
- If patching is not immediately possible: restrict network exposure, apply least-privilege access
- Test the fix in a staging environment first
- Review logs for signs of exploitation
- Monitor for IOCs (Indicators of Compromise)
- Enable automatic security updates
- Set up vulnerability monitoring
- Review and harden security configurations
Exploit Difficulty Assessment
Vulnerability Timeline
CVE details first published to NVD database
Added to this CVE tracking system
Detection Rules & IOCs
No specific detection rules generated for this vulnerability type.
No vendor/product data available.